TABLE I. Dash numbers and characteristics. 1/
Coil
At +25°C
Dash number 2/
voltages
Over temperature range
(v dc) 4/
Speci-
Lead
Lead
Spacer
Coil circuit
Speci-
Speci-
Speci-
Speci-
Speci-
Coil
fied
fied
length
length
resistance current (mA)
mounting
fied
fied
fied
fied
dropout
.500
.187
pads
5/ 7/
pickup
hold
dropout
pickup
hold
Rated
Max
(ref. only)
±.010
value
value
min
(fig.2)
value
value
value
value
ohms
(voltage) (voltage) (voltage) (voltage) (voltage) (V dc)
3/
5/
Max
Min
(V dc)
(V dc)
(V dc)
(V dc)
(V dc)
033
041
049
5.0
7.0
64
78.1 56.8
2.9
2.2
0.8
3.7
2.6
0.7
034
042
050
6.0
10.0
125
48.9 36.3
4.0
2.5
0.9
4.8
3.0
0.8
035
043
051
9.0
15.0
400
23.6 18.1
6.1
3.6
1.1
8.0
4.5
0.9
036
044
052
12.0
20.0
800
16.0 12.5
7.8
4.6
1.3
11.0
5.8
1.0
037
045
053
18.0
30.0
1,600
12.2
9.6
11.3
7.0
1.5
14.5
9.0
1.1
038
046
054
26.5
40.0
3,200
9.0
7.2
15.2
10.8
1.7
19.0
13.0
1.3
039
047
055
36.0
57.0
6,500
6.1
4.9
21.7
14.7
2.3
27.2
19.0
1.7
040
048
056
48.0
75.0
11,000
4.8
3.9
27.8
19.8
2.8
34.8
26.0
2.0
057 6/
---
065 6/
5.0
7.0
64
78.1 56.8
2.9
2.2
0.8
3.7
2.6
0.7
058 6/
---
066 6/
6.0
10.0
125
48.9 36.3
4.0
2.5
0.9
4.8
3.0
0.8
059 6/
---
067 6/
9.0
15.0
400
23.6 18.1
6.1
3.6
1.1
8.0
4.5
0.9
060 6/
---
068 6/ 12.0
20.0
800
16.0 12.5
7.8
4.6
1.3
11.0
5.8
1.0
061 6/
---
069 6/ 18.0
30.0
1,600
12.2
9.6
11.3
7.0
1.5
14.5
9.0
1.1
062 6/
---
070 6/ 26.5
40.0
3,200
9.0
7.2
15.2
10.8
1.7
19.0
13.0
1.3
063 6/
---
071 6/ 36.0
57.0
6,500
6.1
4.9
21.7
14.7
2.3
27.2
19.0
1.7
064 6/
---
072 6/ 48.0
75.0
11,000
4.8
3.9
27.8
19.8
2.8
34.8
26.0
2.0
1/ Each relay possesses high level and low level capabilities. However, relays previously tested or used above 10 mA resistive at 6 V
dc maximum or peak ac open circuits not recommended for subsequent use in low level applications.
2/ The suffix letter L, M, P, or R to designate the applicable failure rate level shall be added to the applicable listed dash number.
Failure rate level (percent per 10,000 cycles): L, 3.0; M, 1.0; P, 0.1; R, 0.01. Example, 033L - - - - - -56R.
3/ Relays supplied with spacer mounting pads (-049 through -056 and -65 through -072) shall have the spacer mounting pad rigidly
attached.
4/ CAUTION: The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
5/ Coil resistance not directly measurable at relay terminals. When rated voltage is applied to the coil terminals, the coil circuit current
must be within the limits shown. Measure at 25°C at nominal voltage for 5 seconds, maximum.
6/ Relays are supplied with a case grounding pin welded to the header (see figures 1 and 2).
7/ Delete "Coil resistance" and substitute "Coil current" test in all inspection tables of MIL-PRF-39016.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business