MIL-PRF-39016/36C
TABLE I. Dash number and characteristics. 1/ 2/
Coil
Specified pickup
Coil
Min coil
Mount
Terminal
Dash
Max coil
resistance
(latch/reset)
voltage (V dc)
current
number
current
(Ref. only)
value (voltage)
3/
ohms
(V dc) 6/
Rated
Max
±10% 5/
(mA)
(mA)
4/
25°C
125°C
4.8
3.6
122.85
165.17
37
7.2
6.0
Wire lead (SP)
No mount
-001
8.6
6.2
68.97
88.12
145
14.5
12.0
Wire lead (SP)
No mount
-002
19.0
14.5
23.78
29.63
975
35.0
26.5
Wire lead (SP)
No mount
-003
4.8
3.6
122.85
165.17
37
7.2
6.0
Solder lug
Flange
-004
8.6
6.2
68.97
88.12
145
14.5
12.0
Solder lug
Flange
-005
19.0
14.5
23.78
29.63
975
35.0
26.5
Solder lug
Flange
-006
1/ Each relay possesses high level and low level capabilities. However, relays previously tested or used above 10
mA resistive at 6 V dc maximum or peak ac open circuits are not recommended for subsequent use in low level
applications.
2/ WARNING: When latching relays are installed in equipment, the latch and reset coils should not be pulsed
simultaneously. Coils should not be pulsed with less than the rated coil voltage.
3/ The suffix letter L, M, P, or R to designate the applicable failure rate level shall be added to the applicable listed
dash number. Failure rate level (percent per 10,000 cycles): L, 3.0; M, 1.0; P, 0.1; R, 0.01.
Example, 001L - - - 006R.
4/ CAUTION: Use of any coil voltage less than the rated voltage will compromise the operation of the relay.
5/ Coil resistance not directly measurable at relay terminals. When rated voltage is applied to the coil terminals
the coil circuit current must be within the limits shown. Measure at 25°C at nominal voltage for 5 seconds
maximum.
6/ A 10 percent increase in latch and reset voltages is allowed during and after rated life.
TABLE II. Qualification inspection and sample size.
Single submission
Group submission
24 units plus 1 open unit for level L
M39016/36-006
24 units plus 1 open unit for level L
at C = 0 1/
at C = 0 1/
33 units plus 1 open unit for level
33 units plus 1 open unit for level
M at C = 0 1/
M at C = 0 1/
Qualification inspection as
Qualification inspection as
applicable.
applicable.
2 units qualification inspection table,
M39016/36-002
Q1.
2 units, qualification inspection table,
M39016/36-001
Q1, and terminal strength,
resistance to soldering heat, and seal.
1/ The number of units required for qualification testing shall be increased as required in Q5, MIL-PRF-39016, if the
relay manufacturer elects to test the number of units permitting one or more failures. Prior to performance of
qualification testing; the relay manufacturer shall preselect the sample size.