MIL-PRF-39016/36C
REQUIREMENTS:
Contact data:
Load ratings:
High level (relay case grounded):
Resistive: 2.0 ampere at 28 V dc. .125 ampere at 115 V ac (60 and 400 Hz). 0.5 ampere at 115 V ac
(60 and 400 Hz) (case ungrounded).
Inductive: 0.5 ampere at 200 mH inductive at 28 V dc.
Lamp: 0.10 ampere at 28 V dc - Life test not required.
Low level: 10 µA to 50 µA at 10 mV to 50 mV dc or peak ac.
Intermediate current: Applicable.
Contact resistance or voltage drop:
Initial: 0.050 ohm maximum.
High level:
During life: Not more than 5 percent of open circuit voltage.
After life: 0.150 ohm maximum.
Low level:
During life: 33 ohms maximum.
After life: 0.150 ohm maximum.
Intermediate current:
During: 1 ohm maximum.
After: .300 ohm maximum.
Contact bounce: 2.0 milliseconds (ms) maximum. (Applicable to failure rate level "L").
Contact stabilization time: 2.5 ms maximum. (Applicable to failure rate levels "M", "P", and "R").
Overload (high level only): 4 ampere resistive at 28 V dc. 1.0 ampere inductive at 28 V dc (ac not applicable).
Neutral screen: Applicable