QUALIFICATION INSPECTION:
Qualification inspection and sample unit size: See table II.
TABLE I. Dash numbers and characteristics. 1/
At 25°C
Dash numbers 2/
Over temperature range
Coil voltage
Speci-
Spreader
(V dc)
Lead
Lead
Coil
Lead
fied
mounting
Speci-
Coil circuit
Speci-
Speci-
Speci-
Speci-
5/
current (mA)
length
length
resis-
length
pick-up
pads
fied
fied
fied
fied
fied
6/ 7/
1.500
.187
tance
.500
value
(fig. 2)
hold
drop-
pickup
hold
drop-
±.010
min
4/
(ref.
value
min
(volt.)
value
value
out
out
3/
(V dc) (volt.)
value
only)
(volt.)
(volt.)
value
Ohms
Max
(V dc)
(volt.)
(V dc)
(V dc)
(volt.)
(V dc)
Max
(V dc)
Rated
Max
Max
Min
017
025
033
041
5.0
8.0
100
50.0
36.3
3.5
1.7
0.23
4.5
2.4
0.15
018
026
034
042
6.0
11
200
30.6
22.7
4.1
2.0
0.28
5.5
2.8
0.18
019
027
035
043
12
22
1,025
12.5
9.7
8.0
4.0
0.63
10
5.6
0.40
020
028
036
044
26.5
45
4,000
7.2
5.7
15.4
8.0
1.37
19
10.4
0.89
021
029
037
045
32
57
6,500
5.4
4.3
17
9.0
1.5
21
12.6
0.95
022
030
038
046
40
75
11,000
4.0
3.2
22
11.2
2.0
27
15.7
1.28
023
031
039
047
9.0
16
630
15.0
11.5
6.3
3.0
0.54
7.8
4.2
0.35
024
032
040
048
18
33
2,300
8.5
6.7
11.6
6.0
0.91
14.5
8.4
0.58
1/ Each relay possesses high level and low level capabilities. However, relays previously tested or used above 10 mA resistive at 6
V dc maximum or peak ac open circuits not recommended for subsequent use in low level applications.
2/ The suffix letter L, M, P, or R to designate the applicable failure rate level shall be added to the applicable listed dash number.
Failure rate level (percent per 10,000 cycles): L, 3.0; M, 1.0; P, 0.1; R, 0.01. Example, 017L - - - - - -048R.
3/ 1.500 leads are inactive for new design.
4/ Relays supplied with spreader mounting pads (-041 through -048) shall have the spreader mounting pad rigidly attached.
5/ CAUTION: The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
6/ Coil resistance not directly measurable at relay terminals. When rated voltage is applied to the coil terminals, the coil circuit
current must be within the limits shown. Measure at 25°C at nominal voltage for 5 seconds, maximum.
7/ Delete "Coil resistance" and substitute "Coil current" test in all inspection tables of MIL-PRF-39016.