MIL-PRF-39016/26F
REQUIREMENTS:
CONTACT DATA:
Load ratings:
High level (relay case grounded):
Resistive:
1.0 ampere at 28 V dc.
250 milliamperes at 115 V ac 60 and 400 Hz case not grounded.
100 milliamperes at 115 V ac 60 and 400 Hz case grounded.
Inductive load: 0.2 ampere at 28 V dc with 0.32 henry inductance.
Lamp: 0.10 ampere at 28 V dc.
Low level: 10 to 50 µA at 10 to 50 mV dc or peak ac.
Intermediate current: Applicable.
Contact resistance or voltage drop:
Initial: 0.10 ohm maximum (0.125 ohm maximum with spreader mounting pad attached).
High level:
During life: Not more than 5 percent of open circuit voltage.
After life: 0.20 ohm maximum (0.225 ohm maximum with spreader mounting pad attached).
Low level:
During life: 33 ohms maximum.
After life: 0.15 ohm maximum (0.175 ohm maximum with spreader mounting pad attached).
Intermediate current:
During: 1 ohm maximum.
After: 0.20 ohm maximum (0.225 ohm maximum with spreader mounting pad attached).
Contact bounce: 1.5 milliseconds maximum (applicable to failure rate level "L").
Contact stabilization time: 2.0 milliseconds maximum (applicable to failure rate levels "M", "P", and "R").
Overload (high level only): Two times rated current. Not applicable to ac load ratings.
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.