MIL-PRF-39016/13K
Overload (high level only): (post overload life test shall be 25,000 cycles).
Resistive: 4 amperes at 28 V dc.
Inductive: 0.6 ampere at 28 V dc. (AC not applicable.)
COIL DATA: See table I.
Operate time: 4.0 ms maximum over temperature range with rated coil voltage.
Release time: 4.0 ms maximum over temperature range from rated coil voltage.
ELECTRICAL DATA:
Insulation resistance: 10,000 megohms minimum, except the resistance between coil and case at high
temperature shall be 1,000 megohms minimum.
Dielectric withstanding voltage:
Sea level
Altitude
V rms (60 Hz)
V rms (60 Hz)
Between case, frame, or enclosure and all contacts in the energized
and de-energized positions.
750
350
Between case, frame, or enclosure and coils.
500
All terminals
Between all contacts and coils.
750
to case
Between open contacts in the energized and de-energized positions.
500
Between contact poles.
750
ENVIRONMENTAL DATA:
Temperature range: -65C to +125C.
Vibration (sinusoidal): MIL-STD-202, method 204. Contact chatter shall not exceed 10 microseconds maximum
for closed contacts, and 1 microsecond maximum closure for open contacts.
Vibration (random): MIL-STD-202, method 214, test condition IG. Contact chatter shall not exceed 10
microseconds maximum for closed contacts, and 1 microsecond maximum closure for open contacts.
Applicable to qualification and group C testing only.
Shock (specified pulse): MIL-STD-202, method 213, test condition B (75 g's). Contact chatter shall not exceed
10 microseconds maximum for closed contacts, and 1 microsecond maximum closure for open contacts.
Magnetic interference: Applicable.
Resistance to soldering heat: Applicable.
Acceleration: 100 G.
4