MIL-PRF-39016/13K
REQUIREMENTS:
CONTACT DATA:
Load ratings:
High level (case grounded 100,000 life cycles, unless otherwise specified):
Resistive:
2 amperes at 28 V dc (50,000 cycles).
1 ampere at 28 V dc.
0.125 ampere at 115 V ac, 60 and 400 Hz.
0.5 ampere at 115 V ac, 60 and 400 Hz (case not grounded).
Inductive load: 0.3 ampere at 28 V dc with 200 millihenries inductance.
Lamp: 0.10 ampere at 28 V dc. (Life test not required.)
Low level: 10 to 50 A at 10 to 50 mV dc or peak ac.
Intermediate current: Applicable.
Contact resistance or voltage drop:
Initial: 0.050 ohm maximum.
High level:
During life: Not more than 5 percent of open circuit voltage.
After life: 0.15 ohm maximum.
Low level:
During life: 33 ohms maximum.
After life: 0.15 ohm maximum.
Intermediate current:
During: 1 ohm maximum.
After: 0.3 ohm maximum.
Contact bounce: 2.0 milliseconds (ms) maximum. (Applicable to failure rate levels "L").
Contact stabilization time: 2.5 milliseconds maximum (applicable to failure rate levels "M", "P", and "R").