MIL-PRF-28776F
0.100, grid pin pattern
TO-5, round pin pattern
FIGURE 8. Mounting arrays for adjacent similar relays.
FIGURE 9. Ambient temperatures.
4.8.14.1 Coil endurance (see 3.19.1). Relays shall be tested for 114 hours minimum as follows:
The coil current shall be tested in accordance with 3.12.3 prior to testing and shall be as specified (see 3.1).
a.
b.
Relays may be mounted as specified in 4.3.5. Each contact terminal shall be connected as specified in
c.
The test chamber shall be controlled to maintain the maximum specified ambient temperature (see 3.1).
d.
Apply the maximum coil voltage (see 3.1) at a cycling rate of 4 ±.4 seconds on and 2 ±.2 seconds off for
114 hours minimum.
Following the test, the coil or coil resistance shall be measured in accordance with 3.12.3 and shall be as
e.
specified (see 3.1).
36
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business