MIL-PRF-28776F
3.5.4 Coils. Coils shall be adequately insulated electrically from the contacts and the case. The resistance and
rated voltage (or current) shall be as specified (see 3.1). Unless otherwise specified (see 3.1), coils shall be
designed for continuous operation at maximum rated voltage and temperature.
3.5.4.1 Terminal identification. When specified (see 3.1), a bead of contrasting color shall be used to designate
FIGURE 1. Symbols and marking for terminals.
3.5.5 Circuit diagram. The circuit diagram, as specified (see 3.1), shall be a terminal view. Circuit symbols shall
be in accordance with IEEE-315. For relays without an orientation tab, the circuit diagram, as specified (see 3.1),
shall be orientated so that when the relay is held with the circuit diagram right side up as shown (see 3.1), and rotated
away from the viewer about a horizontal axis through the diagram until the header terminals face the viewer, then
each terminal shall be in the location shown in the circuit diagram.
3.5.6 Mounting means (see 3.1).
3.5.6.1 Bracket. Mounting brackets shall be an integral part of the relay, securely attached thereto in a manner to
prevent any movement between the relay and the mounting bracket.
3.5.7 Terminals (see 3.1). Terminals shall be as specified herein. Manufacturer may supply hot solder dipped
terminals provided that the hot solder dipping process has been approved by the qualifying activity and when
specified on the individual purchase order (see 6.2.1a). Solder dipped terminals may be .002 inch (0.051 mm) larger
than the maximum dimension specified (see 3.1).
3.5.7.1 Solder-lug terminals. Solder-lug terminals shall be designed to accommodate two conductors, each rated
to carry the maximum rated current of the contact or coil terminated.
3.5.7.2 Wire leads. Wire leads shall be as specified (see 3.1). Optional, shortened wire leads may be supplied
3.5.7.2.1 Wire leads, solder pin (SP). Solder pin wire leads shall be as specified (see 3.1).
3.5.7.3 Plug-in termination. Plug-in terminations shall conform to the arrangements or dimensions as specified
(see 3.1). The mounting arrangement of the relay shall be so designed that the entire weight of the relay will be
suspended and the stability of its mounting will be provided by an auxiliary mounting means other than the electrical
terminals of a socket (see 3.1). Plug-in pin terminals shall provide the operational, environmental, and interface
characteristics to provide a reliable interconnect to gold-plated contacts. One system for gold plating that may be
used is ASTM B488, type 3, class 1.25, knoop hardness 130 to 240, with nickel underplate 50 to 150 microinches
thick. The gold plating system shall enable the product to meet the performance requirements of this specification
and shall be approved by the qualifying activity.