MIL-DTL-19648E
6.2.1 Items not covered by specification sheets. For relays not covered by specification sheets, the
procurement document should specify the following:
a. Title, number, and date of this specification.
b. Title, number, and individual services or manufacturers drawing.
c. Shock level, temperature class, and vibration level (see 1.2.2).
d. Rated heater voltage (see 3.4.1.1).
e. Contact arrangement and contact rating (see 3.4.2).
f. Terminal design (see 3.4.3).
g. Weight of relay (see 3.4.5).
h. Normal operate time (see 3.6.2).
i. Applicable seal test (see 3.7).
j. Applicable acceleration test, if required (see 3.13).
k. Dielectric withstanding voltage (see 3.8).
(1) Test condition letter, if other than D (see 4.7.5.2b).
l. Applicable shock test (see 3.12).
m. Number of sample units (see 4.5).
n. Levels of preservation and packing required (see 5.1 and 5.2).
o. If special or additional identification marking is required (see 5.3).
6.3 First article inspection. Information pertaining to first article inspection of products covered by this
specification should be obtained from the procuring activity for the specific contracts involved (see 3.2).
6.4 Subject (key word) listing.
Temperature class
Vibration level
6.5 PIN. This specification requires a PIN that describes codification and/or classification and
appropriate references to associated documents (see 1.2.1 and 3.1).
23
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business