MS27709H
REQUIREMENTS:
Configurations and dimensions: See figure 1. Lead coding and circuit diagram: See figure 2.
Dash numbers and general characteristics: See table I. Contact data:
Rated contact load: See table II. Maximum contact drop, initial: 0.150 V.
After life test: 0.175 V.
Overload current (NO): 40 amperes dc. Rupture current (NO): 50 amperes dc.
Operating characteristics: See table III.
Duty rating: Continuous.
RFI specification: Not applicable. Electrical data:
Minimum insulation resistance: Initial: 100 megohms.
After life or environmental test: 50 megohms. Dielectric strength:
Sea level, 2-5 seconds:
Coil to case: Auxiliary contacts: All other points:
Altitude, 1 minute (80,000 ft.): 1/
Coil to case: Auxiliary contacts: All other points:
_
1/ Dielectric may be improved by suitable insulation of terminals and wiring after installation.