MS27709H
Inches |
mm |
Inches |
mm |
Inches |
mm |
.002 .005 .010 .016 .035 .040 .062 .138 .144 |
0.05 0.13 0.25 0.41 0.89 1.02 1.57 3.51 3.66 |
.156 .200 .206 .230 .300 .310 .345 .500 .600 |
3.96 5.08 5.23 5.84 7.62 7.87 8.76 12.70 15.24 |
.625 .640 1.025 1.125 1.359 1.437 24.0 |
15.88 16.26 26.04 28.58 34.52 36.50 610 |
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for general information only.
3. Unless otherwise specified, tolerance is ±.010 (0.25 mm).
4. Terminal numbers shall not appear on relay header. There shall be affixed to the relay a legible circuit diagram that identifies each terminal location specified.
5. In the event of a conflict between the test of this document and the references cited herein, the text of this document shall take preference.
6. Referenced Government documents specified in the solicitation are available online at https://assist.daps.dla.mil/quicksearch/ or https://www.assist.daps.dla.mil/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA
19111-5094.and form a part of this document to the extent specified herein.
7. Orientation of solder lugs is optional.
8. Shape of flange is optional within the envelope dimensions shown.
9. Shell material shall be diallyl phthalate type SDG in accordance with ASTM-D5948, or equivalent material as approved by the qualifying activity. Shell shall be filled with encapsulation in accordance with MIL-PRF-23586, grade B, type II, class II, or equivalent filler as approved by the qualifying activity.
FIGURE 1. Configurations and dimensions - Continued.
Lead coding (-5 only) |
|||
Term |
Color |
Term |
Color |
A1 A2 A3 B1 B2 B3 C1 |
Blue Brown Red Yellow Orange Green White-blue |
C2 C3 D1 D2 D3 X1 X2 |
White-brown White-red White-yellow White-orange White-green White Black |
FIGURE 2. Lead coding and circuit diagram.