MS27418L
TABLE III. Rated contact load (amperes per pole) (case grounded).
Type of load |
Life operating cycles x 103 |
28 V dc |
115 V ac, 1 phase |
115/200 V ac, 3 phase 1/ |
See appropriate notes |
|||||||||
Main |
Aux |
Main |
Aux |
Main |
Aux |
|||||||||
NO |
NC |
NO |
NC |
400 Hz |
50/60 Hz |
400 Hz |
60 Hz |
400 Hz |
50/60 Hz |
400 Hz |
60 Hz |
|||
Resistive |
50 |
25 |
25 |
25 |
25 |
25 |
||||||||
Inductive |
10 |
25 |
25 |
25 |
25 |
2/ |
||||||||
Inductive |
10 |
15 |
||||||||||||
Motor |
50 |
20 |
20 |
12 |
20 |
12 |
||||||||
Lamp |
50 |
10 |
10 |
10 |
10 |
10 |
||||||||
Transfer load |
3/ |
|||||||||||||
Mechanical life reduced current |
200 |
6.3 |
6.3 |
6.3 |
6.3 |
6.3 |
||||||||
Mixed loads |
Applicable per specification |
1/ Absence of value indicates relay is not rated for 3 phase applications.
2/ 0.7 pF, inductive.
3/ Transfer load indicates relay is suitable for transfer between unsynchronized ac power supplies at rating indicated.
Environmental characteristics: Temperature range: -70°C to +125°C. Maximum altitude rating: 80,000 feet. Shock g-level: 50 g's.
Duration: 11 ms.
Max duration contact opening: 2 ms. Vibration - sinusoidal:
Operating
G-level 10 g's.
Frequency range 5 - 1,000 Hz. Non-operation.
G-level: 15 g's.
Frequency range: 20 to 2,000 Hz. Acceleration 10 g's.
6
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business