MS27255K
Maximum contact drop initial: 0.150 volt. After life test: 0.175 volt.
Overload current: 40 amperes dc. Rupture current: 50 amperes dc. Duty rating: Continuous.
RFI specification MIL-STD-461.
(Applicable to coil circuits of ac operated relays.)
Conformance inspection:
Performance of groups B and C tests are not applicable.
Group A acceptance reports shall be submitted to the qualifying activity on a yearly basis in order to retain qualification for this military specification sheet.
Qualification by similarity: See MIL-PRF-6106.
NOTES
Referenced documents. In addition to MIL-PRF-6106, this specification sheet references the following documents. (Government documents are available on line at https://assist.daps.dla.mil/quicksearch or www.dodssp.daps.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094). Society of Automotive Engineers documents are available from the Society of Automotive Engineers 400
Commonwealth Drive Warrendale, Pennsylvania, United States, 15096-0001. https://www.sae.org
STANDARDS Department of Defense
MIL-STD-461 - Requirements for the Control of Electromagnetic Interference Characteristics of
Subsystems and Equipment
Custodians: Preparing activity: NAVY - AS DLA - CC
Air Force - 11
DLA - CC (Project 5945-1221-18)
Review activities: Navy - EC
NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using ASSIST Online database at www.dodssp.daps.mil.