MS25465F
TABLE I. Dash numbers and characteristics.
Dash number MS25465- |
Type |
Coil |
Terminal type |
Mounting means |
Max weight in pounds |
D1 |
I |
dc |
Solder hook |
Stud |
0.18 |
A1 |
I |
ac |
Solder hook |
Stud |
0.19 |
AD1 |
I |
ac-dc |
Solder hook |
Stud |
0.19 |
TABLE II. Operating characteristics.
PIN MS25465- |
Coil data |
Time - milliseconds max |
||||||||||||||
Coil |
Rated |
Max |
Max pick-up voltage |
Drop out vol- tage |
Op- erate 3/ |
Rel- ease 4/ |
Contact Bounce |
|||||||||
Volts 1/ |
Freq Hz |
ν Res |
Volts |
Amp |
Nor- mal 2/ |
High temp test |
Cont cur- rent test |
Main |
Aux |
|||||||
NO |
NC |
NO |
NC |
|||||||||||||
D1 |
X1, X2 Y1, Y2 |
28 |
dc |
N/A |
29 |
0.12 |
18 |
18 |
19.8 |
N/A |
25 |
N/A |
2 |
2 |
N/A |
N/A |
A1 |
X1, X2 Y1, Y2 |
115 |
400 5/ |
N/A |
122 |
0.06 |
90 |
90 |
95 |
N/A |
25 |
N/A |
2 |
2 |
N/A |
N/A |
AD1 |
X1, X2 |
115 |
400 5/ |
N/A |
122 |
0.06 |
90 |
90 |
95 |
N/A |
25 |
N/A |
2 |
2 |
N/A |
N/A |
Y1, Y2 |
28 |
dc |
N/A |
29 |
0.12 |
18 |
18 |
19.8 |
N/A |
25 |
N/A |
2 |
2 |
N/A |
N/A |
1/ CAUTION: Use of any coil voltage less than rated coil voltage will compromise the operation of the relay.
2/ Over the temperature range.
3/ With nominal coil voltage.
4/ From nominal coil voltage.
5/ MS25465-A1 and -AD1 may be used on 60 Hz if maximum ambient temperature is limited to +85°C (maximum coil current shall be 0.066 ampere).
TABLE II. Rated contact load (amperes per pole) (case grounded).
Type of load |
Life operat ing cycles 3 x 10 |
28 V dc |
115 V ac, 1 phase |
115/200 V ac, 3 phase 1/ |
See appro priate notes |
|||||||||
Main |
Aux |
Main |
Aux |
Main |
Aux |
|||||||||
NO |
NC |
NO |
NC |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
|||
Resistive |
100 |
5 |
5 |
5 |
4 |
|||||||||
Inductive |
100 |
|||||||||||||
Inductive |
20 |
3 |
3 |
3 |
2 |
|||||||||
Motor |
100 |
1.5 |
1.5 |
1.5 |
1 |
|||||||||
Lamp |
100 |
0.8 |
0.8 |
0.8 |
0.6 |
|||||||||
Transfer load |
2/ |
|||||||||||||
Mechanical life reduced current |
400 |
1.25 |
1.25 |
1.25 |
1 |
|||||||||
Mixed loads |
Applicable per specification |
1/ Absence of value indicates relay is not rated for 3-phase application.
2/ Transfer load indicates relay is suitable for transfer between unsynchronized ac power supplies at rating indicated
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business