MS25395J
11 CAUTION: Use of any coil voltage less than rated coil voltage will compromise the operation of the relay.
21 Over the temperature range.
31 With nominal coil voltage.
41 From nominal coil voltage.
TABLE III. Rated contact load (amperes per pole) (case grounded).
Type of load |
Life operat ing cycles 3 x 10 |
28 V dc |
115 V ac, 1 phase |
1151200 V ac, 3 phase 11 |
See appro priate notes |
|||||||||
Main |
Aux |
Main |
Aux |
Main |
Aux |
|||||||||
NO |
NC |
NO |
NC |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
|||
Resistive |
100 |
5 |
5 |
5 |
4 |
|||||||||
Inductive |
100 |
|||||||||||||
Inductive |
20 |
3 |
3 |
3 |
2 |
|||||||||
Motor |
100 |
1.5 |
1.5 |
1.5 |
1 |
|||||||||
Lamp |
100 |
0.8 |
0.8 |
0.8 |
0.6 |
|||||||||
Transfer load |
21 |
|||||||||||||
Mechanical life reduced current |
400 |
1.25 |
1.25 |
1.25 |
1 |
|||||||||
Mixed loads |
Applicable per specification |
11 Absence of value indicates relay is not rated for 3-phase application.
21 Transfer load indicates relay is suitable for transfer between unsynchronized ac power supplies at rating indicated.
Environm ental characteristics.
Temperature range -70°C to +125°C Max altitude rating 80,000 ft
Shock G-level 50 g's Duration 11 ms Max duration contact opening 10 μs
Vibration - sinusoidal
G-level 10 G Frequency range 5 - 1,500 Hz
Acceleration 15 g's
4
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.