MS25327N
10. Gasket shall provide a reliable seal between the relay and mating socket that will meet the environmental, operational, and interface requirements of the relay with the mating socket. The gasket shall have shore
hardness 20 ±5, thickness .072 ±.008, recessed .047 ±.005 in to bracket. Gasket material according to AMS 3332
has been considered acceptable.
11. Gasket shall provide a reliable seal between the relay and mating socket that will meet the environmental, operational, and interface requirements of the relay with the mating socket. The gasket shall have shore hardness 20 ±5, thickness .062 ±.005 flush with bracket. Gasket material according to AMS 3332 has been
considered acceptable.
FIGURE 1. Dimensions and configurations - Continued.
TABLE I. Dash numbers and characteristics.
Dash number MS25327- |
Type |
Coil |
Terminal type |
Max weight in pounds |
D1 |
I |
dc |
Plug in |
0.43 |
A1 |
I |
ac |
Plug in |
0.45 |
TABLE II. Operating characteristics.
PIN MS 25327- |
Coil data |
Time - (milliseconds maximum) |
|||||||||||||||
Coil |
Rated |
Max |
Max pick-up voltage |
Hold volt- age 2/ |
Drop out volt- age 2/ |
Oper- ate 3/ |
Rel- ease 4/ |
Contact Bounce |
|||||||||
Volts 1/ |
Freq Hz |
Res ν |
Volts |
Amp |
Nor- mal 2/ |
High temp test |
Cont cur- rent test |
Main |
Aux |
||||||||
NO |
NC |
NO |
NC |
||||||||||||||
D1 |
X1,X2 |
28 |
dc |
N/A |
29 |
0.350 |
18 |
19.5 |
22.5 |
7.0 |
1.5 |
20 |
20 |
2 |
2 |
--- |
--- |
A1 |
X1,X2 |
115 |
400 5/ |
N/A |
122 |
0.073 |
90 |
95 |
103 |
30 |
5.0 |
25 |
50 |
2 |
2 |
--- |
--- |
1/ CAUTION: Use of any coil voltage less than rated coil voltage will compromise the operation of the relay.
2/ Over the temperature range.
3/ With rated coil voltage.
4/ From rated coil voltage.
5/ MS25272-A1 may be used on 60 Hz if maximum ambient temperature is limited to 85°C (maximum coil current shall be 0.077 ampere).
TABLE III. Rated contact load (amperes per pole) (case grounded).
Type of load |
Life operat ing cycles 3 x 10 |
28 V dc |
115 V ac, 1 phase |
115/200 V ac, 3 phase 1/ |
See appro priate notes |
|||||||||
Main |
Aux |
Main |
Aux |
Main |
Aux |
|||||||||
NO |
NC |
NO |
NC |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
|||
Resistive |
100 |
10 |
10 |
10 |
6 |
10 |
6 |
|||||||
Inductive |
100 |
|||||||||||||
Inductive |
20 |
6 |
6 |
6 |
4 |
6 |
4 |
|||||||
Motor |
100 |
4 |
4 |
4 |
3 |
4 |
3 |
|||||||
Lamp |
100 |
2 |
2 |
2 |
1.5 |
2 |
1.5 |
|||||||
Transfer load |
2/ |
|||||||||||||
Mechanical life reduced current |
400 |
2.5 |
2.5 |
2.5 |
2 |
2.5 |
2 |
|||||||
Mixed loads |
Applicable per specification |
1/ Absence of value indicates relay is not rated for 3-phase application.
2/ Transfer load indicates relay is suitable for transfer between unsynchronized ac power supplies at rating indicated.
3