MS25031M
Electrical characteristics.
Minimum insulation resistance, initial 100 megohms. After life or environmental tests 50 megohms. Dielectric strength (sea level). 2-5 seconds.
Initial After life tests
28 V dc |
115 V ac |
28 v dc |
115 V ac |
|
Coil to case |
1,250 V rms |
N/A |
1,000 |
N/A |
Aux contacts |
1,250 V rms |
N/A |
1,000 |
N/A |
All other points |
1,250 V rms |
1,500 |
1,000 |
1,125 |
Dielectric strength (altitude) 1 minute. |
||
Initial |
After life tests |
|
Coil to case |
500 |
N/A |
Aux contacts |
500 |
N/A |
All other points |
500 |
500 |
Max contact drop initial 0.150 volt. After life test 0.175 volt.
Overload current (NO) 800 amperes.
Rupture current 1,000 amperes. Duty rating Continuous.
RFI specification
(Applicable to coil circuits of ac operated relays).
Conformance inspection.
Performance of groups B and C tests are not applicable.
Group A acceptance reports shall be submitted to the preparing activity on a yearly basis in order to retain qualification for this military standard sheet.
Qualification by similarity: See MIL-PRF-6106.
Dash number MS25031- |
Vibration level |
||||
5-10 Hz |
10-55 Hz |
55-250 Hz |
250-500 Hz |
500-1500 Hz |
|
D1B |
.08 DA |
.06 DA |
2 g's |
2 g's |
Custodians: Preparing activity: Navy - AS DLA - CC
Air Force - 11
DLA - CC (Project 5945-1221-06)
Review activities: Air Force - 99
Navy - EC
NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using ASSIST Online database at www.dodssp.daps.mil.