MS24568K
Vibration - sinusoidal
Sinusoidal 3 inches excursion 5 to 36 Hz
G-level |
20 G |
Frequency range 36 to 500 Hz |
15 G |
500 to 1,000 Hz |
|
10 G |
1,000 to 2,000 Hz |
|
Non-operate |
15 G |
20 to 2,000 Hz |
Acceleration |
15 G |
Electrical characteristics.
Insulation resistance, initial 100 megohms. After life or environmental tests 50 megohms.
Dielectric strength (sea level).
Initial |
After life tests |
|
Coil to case |
1,000 V rms |
1,000 V rms |
Aux contacts All other points |
2,000 V rms |
1,500 V rms |
Dielectric strength (altitude).
80,000 ft Coil to case 500 V rms Aux contacts
All other points 700 V rms
Max contact drop initial: 0.150 volt. After life test: 0.175 volt.
Overload current (NO): 40 amperes dc,
60 amperes ac
Rupture current 60 amperes dc,
80 amperes ac.
Duty rating: Continuous. RFI specification: MIL-STD-461.
(Applicable to coil circuits of ac operated relays).
Conformance inspection.
Performance of groups B and C tests not applicable to dash numbers-A1 and A2. Qualification by similarity: See MIL-PRF-6106.
4
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business