MS24192P
TABLE I. General characteristics.
Part or identifying number |
Type |
Coil |
Terminal type |
Mounting |
Maximum weight in pounds |
MS24192-D1 |
II |
dc |
Stud |
Plate |
1.2 |
TABLE II. Rated contact load (amperes per pole) case grounded.
Type of load |
Life operat ing cycles 3 x 10 |
28 V dc |
115 V ac, 1 phase |
1151200 V ac, 3 phase 11 |
|||||||||
Main |
Aux |
Main |
Aux |
Main |
Aux |
||||||||
NO |
NC |
NO |
NC |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
||
Resistive |
50 |
25 |
25 |
25 |
|||||||||
Inductive |
10 |
25 |
25 |
25 |
|||||||||
Inductive |
|||||||||||||
Motor |
50 |
25 |
25 |
25 |
|||||||||
Lamp |
|||||||||||||
Transfer load |
|||||||||||||
Mechanical life reduced current |
100 |
6.3 |
6.3 |
6.3 |
|||||||||
Mixed loads |
Applicable in accordance with MIL-PRF-6106. |
11 Absence of value indicates relay is not rated for 3 phase application.
21 Transfer load indicates relay is suitable for transfer between unsynchronized ac power supplies at rating indicated.
TABLE III. Operating characteristics.
PIN MS 24192- |
Coil data |
Time - milliseconds maximum |
|||||||||||||||
Coil |
Rated |
Max |
Max pick-up voltage |
Hold vol- tage 21 |
Drop out vol- tage 21 |
Oper -ate 31 |
Rel- ease 41 |
Bounce 51 |
|||||||||
Volts 11 |
Freq Hz |
ν Res |
Volts |
Amp |
Nor- mal 21 |
High temp test |
Cont cur- rent test |
Main |
Aux |
||||||||
NO |
NC |
NO |
NC |
||||||||||||||
D1 |
X1,X2 |
28 |
dc |
60 ±10 |
29 |
0.58 |
18 |
21 |
22.5 |
7.0 |
1.5 |
20 |
15 |
3.0 |
--- |
--- |
--- |
11 CAUTION: Use of any coil voltage less than rated coil voltage will compromise the operation of the relay.
21 Over the temperature range.
31 With rated coil voltage.
41 From rated coil voltage.
51 Bounce time after life tests is 6 rms.
4
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business