MS24184M
Shock g-level: 25 g's.
0uration: 6-9 ms.
Maximum duration contact opening: 2 ms. Vibration - sinusoidal: See table IV. Acceleration: 15 g's.
Part or Identifying Number (PIN): MS24184- (plus applicable dash number from table I). Qualification by similarity: See MIL-PRF-6101.
TABLE I. PIN and general characteristics.
1/ 2/ Part number MS24184- |
Type |
Coil type |
Terminal type |
Mounting or mating socket |
Auxiliary contacts |
Maximum weight in pounds |
01 |
I |
dc |
Stud |
Flange |
No |
2.4 |
02 |
I |
dc |
Stud |
Flange |
Yes |
2.5 |
1/ MS24184-A1 has been canceled without replacement.
2/ The term Part or Identifying Number (PIN) is equivalent to the former term MS dash number.
TABLE II. Rated contact load (amperes per pole) case grounded. 1/
Type of load |
Life operat ing cycles 3 x 10 |
28 V dc |
115 V ac, 1 phase |
See appro- priate notes |
||||||
Main |
Aux |
Main |
Aux |
|||||||
NO |
NC |
NO |
NC |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
|||
Resistive |
50 |
300 |
5 |
5 |
300 |
5 |
||||
Inductive |
50 |
100 |
5 |
5 |
5 |
|||||
Motor |
50 |
250 |
150 |
|||||||
Lamp |
.75 |
.75 |
.75 |
|||||||
Transfer load |
3/ |
|||||||||
Mechanical life reduced current |
100 |
75 |
1.25 |
1.25 |
75 |
1.25 |
||||
Mixed loads |
50 |
10 |
Applicable per MIL-PRF-6106 |
1/ Absence of value means parameter is not applicable to this specification sheet.
2/ Off time for motor load shall be 6 seconds minimum.
3/ Transfer load indicates relay is suitable for transfer between unsynchronized ac power
supplies at the rating indicated.
4