MS24166J
TABLE II. Rated contact load (amperes per pole) case grounded.
Type of load |
Life operating cycles x 103 |
28 V dc |
115 V ac, 1 phase |
1151200 V ac, 3 phase 11 |
|||||||||
Main |
Aux |
Main |
Aux |
Main |
Aux |
||||||||
NO |
NC |
NO |
NC |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
||
Resistive |
50 |
50 |
|||||||||||
Inductive |
10 |
50 |
|||||||||||
Motor |
50 |
50 |
|||||||||||
Lamp |
50 |
25 |
|||||||||||
Transfer load 21 |
|||||||||||||
Mechanical life (reduced current) |
100 |
12.5 |
|||||||||||
Mixed loads |
50 |
5 |
11 Absence of value indicates that relay is not rated for 3 phase applications.
21 Transfer load indicates that relay is suitable for transfer between unsynchronized ac power supplies at the rating indicated.
TABLE III. Operating characteristics.
PIN MS24166- |
Coil data |
Time - (milliseconds maximum) |
|||||||||||||||
Coil |
Rated |
Max |
Max pick-up voltage |
Hold voltage 21 |
Drop- out volt- age 21 |
Operate 31 |
Release 41 |
Bounce |
|||||||||
Volts 11 |
Freq. (Hz) |
Res Ω +10% -15% |
Volts |
Am- pere |
Norm- al 21 |
High temp test |
Cont Cur- rent test |
Main |
Aux |
||||||||
NO |
NC |
NO |
NC |
||||||||||||||
D1 |
X1,X2 |
28 |
dc |
94 |
29 |
.35 |
18 |
21 |
22.5 |
7.0 |
1.5 |
20 |
10 |
5.0 |
|||
D2 |
X1,X2 |
28 |
dc |
94 |
29 |
.35 |
18 |
21 |
22.5 |
7.0 |
1.5 |
20 |
10 |
5.0 |
11 CAUTION: Use of any coil voltage less than rated coil voltage will compromise the operation of the relay.
21 Over the temperature range.
31 With rated coil voltage.
41 From rated coil voltage.
TABLE IV. Vibration levels (sinusoidal).
5-10 Hz |
10-55 Hz |
55-250 Hz |
250-500 Hz |
500-1500 Hz |
0.08 |
.06 DA |
2 g's |
2 g's |
N1A |
Custodians: Preparing activity: Navy - AS DLA - CC
Air Force - 11
DLA - CC
Review activity: Air Force - 99
(Project 5945-1206-07)
5
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business