MIL-R-83726/8E
Recycle characteristics:
Before time out: Control power must remain off at least 25 milliseconds or 1 percent of the nominal time delay, whichever is greater, after which reapplication of control power for 25 milliseconds minimum will recycle the timer with a loss in timing no greater than 10 percent.
After time out: Reapplication and subsequent removal of control power will recycle the timer. Control power must be applied for 25 milliseconds or 1 percent of the total time delay, whichever is greater, to insure a loss in timing accuracy no greater than 10 percent.
Polarity protection: The unit will be inoperative during, and undamaged by, reversal of the input polarity.
ELECTRICAL DATA:
Insulation resistance at 500 V dc 1/:
Initial: 1,000 megohms minimum.
After life or environmental tests: 500 megohms minimum. Dielectric withstanding voltage (sea level):
Input (1 and 9) 1/ :
Initial: 1,000 V rms. After life: 1,000 V rms
All other points 2/:
Initial: 1,000 V rms. After life: 500 V rms.
Dielectric withstanding voltage (altitude):
Input (1 and 9): 350 V rms 1/
All other points: 350 V rms 2/
Transients: In accordance with MIL-STD-704 for 28 V dc system (figure 11).
1/ Input terminals 1, 5, and 9 must be connected together during this test.
2/ All pins to case for this test.