Load ratings:
MIL-R-83726/13J
Resistive: 300 milliamperes at 25°C, derated to 100 milliamperes at +125°C. Minimum load current of 10 milliamperes is required.
Inductive: Three MIL-PRF-39016/6 relays or equivalent with 26.5 V dc coil voltage. Lamp load: Two M6363/8-5 lamps in accordance with MIL-DTL-6363 or equivalent. Motor load, dc: Not applicable.
Inductive load, ac: Three MIL-PRF-39016/6 relays or equivalent. Resistive load, ac: Not applicable.
Motor load, ac: Not applicable.
Load suppression: Suppression for inductive loads for output protection is provided within the unit. Voltage drop: 2.5 volts maximum at -55°C and +25°C, 2.0 volts maximum at +125°C.
Leakage current: 1 microampere maximum at 25°C, 10 microamperes maximum at +125°C. Continuous current: Not applicable.
Overload: Not applicable. Electrical data:
Insulation resistance: 1,000 megohms minimum at 500 V dc. 1/
Dielectric withstanding voltage: 500 V rms, 60 Hz, (sea level). 1/
Transients: In accordance with MIL-STD-704 for 28 V dc system (see figure 11).
1/ Measured between all terminals tied together to the case.