Minimum voltage continuous current test: 23.5 V dc. Maximum current at 25°C: 0.150 ampere.
Release time delay: See table I.
Control current: 20 milliamperes maximum. Control pulse duration: 50 milliseconds minimum. Operate time: 50 milliseconds maximum.
Electrical data:
Insulation resistance at 500 V dc: 1/
Initial: 1,000 megohms minimum.
After life or environmental tests: 500 megohms minimum. Dielectric strength (sea level):
Initial |
After life tests |
|
Input (X1 - X2 - Y1) 1/ |
1,000 V rms |
1,000 V rms |
All other points |
1,250 V rms |
1,000 V rms |
Dielectric strength (altitude): 80,000 feet. 1/
Input (X1 - X2 - Y1): 350 V rms. 1/
All other points: 350 V rms.
Transients: In accordance with MIL-STD-704 for 28 V dc system (figure 11).
1/ Input terminals X1, X2, and Y1 shall be connected together during this test.