MIL-R-83726112E
NOTES:
1. Dimensions are in inches.
2. Unless otherwise specified, tolerance is ±.010 (0.25 mm) for three place decimals and ±.03
3. (0.8 mm) for two place decimals.
4. Metric equivalents are given for general information only.
5. Terminal numbers shall not appear on the relay header. There shall be affixed to the relay a permanent legible schematic diagram that identifies each terminal location specified.
FIGURE 1. Outline dimensions and configuration of relay - Continued.
TABLE I. Dash numbers and time delay characteristics. 11
Dash number |
Time delay (seconds) ±10% |
Dash number |
Time delay (seconds) ±10% |
Dash number |
Time delay (seconds) ±10% |
Dash number |
Time delay (seconds) ±10% |
-1000 -5000 -7500 -1001 -2001 -3001 -4001 -5001 -6001 -7001 -8001 -9001 -1002 |
21 .100 21 .500 21 .750 1 2 3 4 5 6 7 8 9 10 |
-1202 -1402 -1602 -1802 -2002 -2202 -2502 -3002 -3502 -4002 -4502 -5002 -5502 -6002 |
12 14 16 18 20 22 25 30 35 40 45 50 55 60 |
-6502 -7002 -7502 -8002 -8502 -9002 -9502 -1003 -1103 -1203 -1303 -1403 -1503 -1603 |
65 70 75 80 85 90 95 100 110 120 130 140 150 160 |
-1703 -1803 -1903 -2003 -2103 -2203 -2303 -2403 -2503 -2603 -2703 -2803 -2903 -3003 |
170 180 190 200 210 220 230 240 250 260 270 280 290 300 |
11 Additional time delay relays within the .100 to 300 second delay range are available. To establish
Part or Identifying Numbers (PIN's) not listed in table I (see "PIN" herein).
21 Add ±10 milliseconds to ±10 percent tolerance.
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business