Physical:
Terminal strength: 5 ±0.5 pounds pull. Sealed by welding: Optional.
MIL-R-5757/7G
Dimensions and configuration: See figure 1 and figure 2. Terminations: See figure 1 and figure 2.
Weight: 0.2 pound maximum. Life test requirements:
High level (applicable to M5757/7-001): 100,000 cycles at rated load. Low level: (applicable to M5757/7-003): 100,000 cycles at rated load. Minimum current: Level II, 50,000 cycles.
Verification:
Periodic inspection: Groups B and C inspections are not applicable. Group A.
a. Group A1: Run-in (applicable to -003 low level relays only). This subgroup may be waived at the discretion of the qualifying activity if fully tested MIL-PRF-39016/6 relays are used internally.
b. Group A2: 100 percent.
c. Dielectric withstanding voltage:
(1) Tests to be conducted at sea level rating only.
(2) Duration of application: 5-10 seconds at a 10 percent increase in the dielectric strength voltage. Qualification: See table I or table II as applicable.
TABLE I. Qualification inspection and sample size.
Part or Identifying Number (PIN) M5757/7 |
Number of sample units |
-001 |
16 units plus 1 open unit. Qualification inspection as applicable. |
-003 |
12 units plus 1 open unit. Qualification inspection as applicable. |
7
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business