MIL-R-5757/1K
Physical data:
Terminal strength: 5 ±0.5 pound pull. Sealed by welding: Optional.
Dimensions and configuration: See figure 1 and figure 2. Terminations: See figure 1 and figure 2.
Weight: 0.27 pound maximum. Life test requirements:
High level: 100,000 cycles. Low level: 100,000 cycles.
Intermediate current (level II): 50,000 cycles. VERIFICATION:
Group A.
a. Group A1: Run-in (applicable to -021, -026, -027, and -028 relays only). This subgroup may be waived at the discretion of the qualifying activity if fully tested MIL-PRF-39016/6 relays are used internally.
b. Group A2: 100 percent.
c. Dielectric withstanding voltage:
(1) Tests to be conducted at sea level rating only.
(2) Duration of application: 5-10 seconds at a 10 percent increase in the dielectric strength voltage. Qualification inspection: See table I or table II as applicable.