MIL-R-39016/39F
Electrical data:
Insulation resistance: 1,000 megohms minimum, except the resistance between coil and case at high temperature shall be 500 megohms, or greater.
Dielectric withstanding voltage: Sea level:
Between case, frame, or enclosure, and all
contacts in the energized and deenergized positions - - - - - - - - 1,000 V rms (60 Hz) Between case, frame, or enclosure and coils - - - - - - - - - - - - - 500 V rms (60 Hz) Between all contacts and coil(s) - - - - - - - - - - - - - - - - - - - - - - 1,000 V rms (60 Hz)
Between open contacts in the energized and deenergized
positions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 500 V rms (60 Hz) Between contact poles - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1,000 V rms (60 Hz)
Altitude:
Between all terminals to case - - - - - - - - - - - - - - - - - - - - - - - 350 V rms (60 Hz) Environmental data:
Temperature range: -65°C to +125°C.
Vibration (sinusoidal): Method 204, MIL-STD-202. Contact chatter shall not exceed 10 µs maximum for closed contacts, and 1 µs maximum closure for open contacts.
Vibration (random): Method 214, MIL-STD-202, test condition IG. Contact chatter shall not exceed 10 µs maximum for closed contacts, and 1 µs maximum closure for open contacts.
Shock (specified pulse): Method 213, MIL-STD-202, test condition A, 50 g's, (see figure 1, HFM); test condition B, 75 g's, (see figure 1, RVFM and NM). Contact chatter shall not exceed 10 µs maximum for closed contacts and 1 µs maximum closure for open contacts.
Resistance to soldering heat: Applicable. Physical data:
Terminals: See figure 1 and table I.
Terminal strength: 3 pounds ± 0.2 pound (pull). Solderability: Applicable.
Dimensions and configurations: See figure 1. Weight: 30 grams (1.06 ounce) maximum.
Identification marking (full): Applicable.
6
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business