TABLE I. Dash numbers and characteristics. 1/
Dash no. |
Mounting style (see figure 1) |
Terminal code |
Coil voltage (V dc) |
At +25qC |
Over temperature range |
||||||
Coil resistance ohms ±10% |
Specified pickup value (voltage) (V dc) |
Specified hold value (voltage) (V dc) |
Specified dropout value (voltage) (V dc) |
Specified pickup value (voltage) (V dc) |
Specified hold value (voltage) (V dc) |
Specified dropout value (voltage) (V dc) |
|||||
Rated 2/ |
Max |
||||||||||
-001 |
RVFM |
SL |
26.5 |
32.0 |
500 |
13.5 |
7.0 |
2.0 |
18.0 |
11.5 |
1.0 |
-002 |
RVFM |
SP |
26.5 |
32.0 |
500 |
13.5 |
7.0 |
2.0 |
18.0 |
11.5 |
1.0 |
-003 |
NM |
SL |
26.5 |
32.0 |
500 |
13.5 |
7.0 |
2.0 |
18.0 |
11.5 |
1.0 |
-004 |
NM |
SP |
26.5 |
32.0 |
500 |
13.5 |
7.0 |
2.0 |
18.0 |
11.5 |
1.0 |
-005 |
HFM |
SL |
26.5 |
32.0 |
500 |
13.5 |
7.0 |
2.0 |
18.0 |
11.5 |
1.0 |
-006 |
HFM |
SP |
26.5 |
32.0 |
500 |
13.5 |
7.0 |
2.0 |
18.0 |
11.5 |
1.0 |
-007 |
RVFM |
SL |
12.0 |
16.5 |
117 |
6.6 |
3.4 |
1.0 |
8.8 |
5.65 |
0.48 |
-008 |
RVFM |
SP |
12.0 |
16.5 |
117 |
6.6 |
3.4 |
1.0 |
8.8 |
5.65 |
0.48 |
-009 |
NM |
SL |
12.0 |
16.5 |
117 |
6.6 |
3.4 |
1.0 |
8.8 |
5.65 |
0.48 |
-010 |
NM |
SP |
12.0 |
16.5 |
117 |
6.6 |
3.4 |
1.0 |
8.8 |
5.65 |
0.48 |
-011 |
HFM |
SL |
12.0 |
16.5 |
117 |
6.6 |
3.4 |
1.0 |
8.8 |
5.65 |
0.48 |
-012 |
HFM |
SP |
12.0 |
16.5 |
117 |
6.6 |
3.4 |
1.0 |
8.8 |
5.65 |
0.48 |
-013 |
RVFM |
SL |
6.0 |
8.5 |
32 |
3.4 |
1.7 |
0.5 |
4.55 |
2.9 |
0.24 |
-014 |
RVFM |
SP |
6.0 |
8.5 |
32 |
3.4 |
1.7 |
0.5 |
4.55 |
2.9 |
0.24 |
-015 |
NM |
SL |
6.0 |
8.5 |
32 |
3.4 |
1.7 |
0.5 |
4.55 |
2.9 |
0.24 |
-016 |
NM |
SP |
6.0 |
8.5 |
32 |
3.4 |
1.7 |
0.5 |
4.55 |
2.9 |
0.24 |
-017 |
HFM |
SL |
6.0 |
8.5 |
32 |
3.4 |
1.7 |
0.5 |
4.55 |
2.9 |
0.24 |
-018 |
HFM |
SP |
6.0 |
8.5 |
32 |
3.4 |
1.7 |
0.5 |
4.55 |
2.9 |
0.24 |
1/ Each relay possesses high level and low level capabilities. However, relays previously tested or used above 10 mA resistive at 6 V dc maximum or peak ac open circuit are not recommended for subsequent use in low level applications.
2/ CAUTION: The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business