MIL-PRF-6106/39F
REQUIREMENTS:
CONTACT DATA:
Life: Unless otherwise specified, 100,000 cycles.
Operational reliability: Applicable, the alternate low level method shall be used.
Load ratings.
High level (relay case grounded).
Resistive: 5 amperes at 28 V dc, 115 V ac, 400 Hz, 1 phase, 115/200 V ac, 400 Hz, 3 phase.
Inductive: 3 amperes at 28 V dc, 5 amperes at 115 V ac, 400 Hz, 1 phase; 5 amperes at 115 V ac, 400
Hz, 3 phase (Life 20,000 cycles).
Motor: 2 amperes at 28 V dc, 3 amperes at 115 V ac, 400 Hz, 1 phase, 5 amperes at 115 V ac, 400 Hz, 3
phase.
Lamp: 1 ampere at 28 V dc, 1 ampere at 115 V ac, 400 Hz, 1 phase.
Low level: 10 to 50 A at 10 to 50 mV dc or peak ac. 1/ 2/ 3/
Intermediate current: Applicable.
Transfer load: Not applicable.
Mechanical life (reduced current): 1.25 amperes at 28 V dc, 115 V ac, 400 Hz, 1 phase, 115 V ac, 400 Hz,
3 phase (Life, 400,000 cycles).
Mixed loads: Applicable. 1/
Contact voltage drop or resistance. 2/ 3/
High level:
Initial: 0.150 volt maximum.
After life: 0.175 volt maximum.
Low level:
Initial: 0.050 ohm maximum.
Afterlife: 0.150 ohm maximum.
Contact bounce: 0.5 millisecond maximum.
_________
1/ Relay shall be capable of switching low level while switching any of the other rated loads on adjacent contacts.
2/ For low level, the following shall apply:
a. During endurance and operational reliability testing, contact load shall be 10 to 50 microamperes, 10 to 50
millivolts open circuit voltage, 100 ohms maximum contact resistance.
b. Static contact resistance shall be performed at 50 mA maximum, 50 mV maximum.
3/ For group A contact voltage drop test, high level testing shall be performed first, followed by low level testing. The
contacts shall not make or break the high level load.