MIL-PRF-6106/38D
Inches
mm
Inches
mm
Inches
mm
.001
0.03
.106
2.69
.300
7.62
.002
0.05
.133
3.38
.312
7.92
.003
0.08
.140
3.56
.410
10.41
.005
0.13
.141
3.58
.450
11.43
.025
0.64
.150
3.81
.640
16.26
.030
0.76
.155
3.93
.810
20.57
.031
0.79
.156
3.96
.850
21.59
.040
1.02
.170
4.32
1.062
26.97
.053
1.34
.190
4.82
1.070
27.18
.075
1.90
.210
5.33
1.078
27.38
.095
2.52
.225
5.72
1.280
32.51
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for general information only.
3. Unless otherwise specified, tolerances are ±.010 (0.25mm).
4. There shall be affixed to the relay a legible circuit diagram that identifies each terminal location specified.
5. These relays are polarized bistable.
6. Permanent magnet drive consists of a permanent magnet with its flux path switched and combined with the
electromagnetic flux.
7. Applicable to configuration C only. The circuit diagram, manufacturer's PIN, and the military PIN shall be marked
on the near side. The remaining portion of the nameplate data shall be marked on the far side.
8. Applicable to configuration C only. Relays shall be marked with the manufacturer's name or source code and date
code. In addition, ER relays shall be marked with the serial number. Marking shall appear with the bottom of the
print adjacent to the near side.
9. Socket pin terminals shall provide the operational, environmental, and interface characteristics to provide a
reliable interconnect to gold-plated contacts. Terminals shall be gold plated. One system for gold plating that
may be used is ASTM B488, type 3, class 1.25 with a nickel underplate of 50 to 150 microinches thick. The gold
plating system shall enable the product to meet the performance requirements of this specification and shall be
approved by the qualifying activity.
10. Gasket shall provide a reliable seal between the relay and mating socket that will meet the environmental,
operational, and interface requirements of the relay with the mating socket. The gasket shall have shore
hardness 25 ±5, thickness .040±.005. Gasket material according to SAE-AMS3332 has been considered
acceptable.
11. Indicated terminals shall be identified by a contrasting bead.
FIGURE 1. Relay, outline drawing - Continued.
5
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business