MIL-PRF-6106/33E
TABLE II. Operating characteristics.
Coil data
Time (milliseconds maximum)
Contact Bounce
Nominal
Maximum
Max pickup voltage
Drop
Rel-
Break
Hold
Back
Coil
Oper
out
Nom-
Res.
Volts
Amp
Volts
High
Cont
Main
Auxiliary
10%
lease
bounce
inal
volt-
EMF
dia-gram
-ate
volt-
dc
dc
temp
curr-
NO only
at
at
age
V dc
age
test
ent
NO
NC
NO
NC
71C
25C
max
test
V dc
V dc
1
28
60
32
.6
18
19
21
1.5
9.0
NA
35
15
4
NA
4
4
NA
.
2 and 3
28
60
32
6
18
19
21
1.5
9.0
42
35
15
4
NA
4
4
0.1
1/ Over temperature range.
2/ Must pass random vibration test using a 9 V dc hold voltage 25C.
TABLE III. Rated contact load endurance (ampere per pole) ase grounded.
28 V dc
28 V dc/115
Type of load
(Endurance)
400 Hz
life operating
3
auxiliary
Main
cycles X 10
NO
NC
D.B.
S.B.
Resistive
50
400
---
5
5
Inductive
20
150
---
5
3
Motor 1/ 2/
50
250
---
Lamp
1
1
Mechanical life
Reduced current
100
100
Mixed loads
Not applicable
1/ Off time for motor load test shall be 6 seconds maximum.
2/ Shall also meet 20,000 cycles of special motor load as specified in table IV.
7
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business