MIL-PRF-39016/9J
1/ Each relay possesses high level and low level capabilities. However, relays previously tested or used above 10
mA resistive at 6 V dc maximum or peak ac open circuits not recommended for subsequent use in low level
applications.
2/ The suffix letter L, M, P, or R, to designate the applicable failure rate level, shall be added to the applicable listed
dash number. Failure rate level (percent per 10,000 cycles): L, 3.0; M, 1.0; P, 0.1; R, 0.01. Example, 013L - - - -
- - -077R.
3/ CAUTION: The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
4/ 1.500 leads are inactive for new design.
5/ Relays supplied with spreader mounting pads (-071 through -077, -099 through -105, and -106 through -112) shall
have the spreader mounting pad rigidly attached.
QUALIFICATION INSPECTION:
Qualification inspection and sample size: See table II.
TABLE II. Qualification inspection and sample size. 1/
Single submission
Group submission
18 units plus 1 open unit for
M39016/9-062
18 units plus 1 open unit for
level L at C = 0 2/
or
level L at C = 0 2/
M39016/9-069
33 units plus 1 open unit for
33 units plus 1 open unit for
level M at C = 0 2/
level M at C = 0 2/
Qualification inspection as
Qualification inspection as
applicable
applicable
M39016/9-057
2 units each PIN
M39016/9-058
Qualification inspection,
M39016/9-059
Q1.
M39016/9-060
M39016/9-061
M39016/9-063
1 unit terminal strength and
M39016/9-090
solderability
or
M39016/9-064
M39016/9-065
M39016/9-066
M39016/9-067
M39016/9-068
M39016/9-070
1 unit terminal strength and
M39016/9-097
solderability
1/ Figure 1 only - For retention of qualification or extension of qualification to lower failure rate
levels, all life test data accumulated on MIL-PRF-39016/11, /15, /16, /20, and /21 may be used
in addition to MIL-PRF-39016/9 data. Qualification to figure 1 automatically qualifies round
relays to figure 2.
Figure 2 only - For retention of qualification or extension of qualification to lower failure rate
levels, all life test data accumulated on MIL-PRF-39016/11, /15, /16, /20, and 21 may be used
in addition to MIL-PRF-39016/9 data. Prior to performance of retention of qualification testing,
the relay manufacturer shall pre-select the sampling plan.
2/ The number of units required for qualification testing shall be increased as required in Q5, MIL-
PRF-39016, if the contractor elects to test the number of units permitting one or more failures.
Prior to performance of qualification testing, the relay manufacturer shall pre-select the
sampling plan.
9