MIL-PRF-39016/9J
Qualification inspection (reduced testing) and sample size: See table III.
Figure 1 only - If the relays produced for MIL-PRF-39016/9 are similar in construction and design except for the
diodes and coil assembly, as applicable, to the relays produced for MIL-PRF-39016/11, /15, /16, /20, or /21,
then reduced testing for qualification of MIL-PRF-39016/9 relays may be performed concurrent with or
subsequent to successful qualification of MIL-PRF-39016/11, /15, /16, /20, or /21. For reduced testing, see
table III.
Figure 2 only - If the relays produced for MIL-PRF-39016/9 are similar in construction and design except for the
diodes and coil assembly, as applicable, to the relays produced for MIL-PRF-39016/11, /15, /16, /20, or /21,
then reduced testing for qualification of MIL-PRF-39016/9 relays may be performed concurrent with or
subsequent to successful qualification of MIL-PRF-39016/11, /15, /16, /20, or /21.
TABLE III. Qualification inspection (reduced testing).
Inspection
2 units each coil voltage - Q1 of qualification
inspection table.
1 unsealed sample unit for internal examination.
SUPERSESSION DATA:
Supersession data: See table IV.
11