MIL-PRF-39016/41E
QUALIFICATION INSPECTION:
Qualification inspection and sample size: See table II.
TABLE II. Qualification inspection and sample size. 1/
Single submission
Group submission
18 units plus 1 open unit for
M39016/41-036
18 units plus 1 open unit for
level L at C = 0 2/
level L at C = 0 2/
33 units plus 1 open unit for
33 units plus 1 open unit for
level M at C = 0 2/
level M at C = 0 2/
Qualification inspection as
Qualification inspection as
applicable
applicable
M39016/41-033
2 units each part number
M39016/41-034
Qualification inspection
M39016/41-035
Q1.
M39016/41-037
M39016/41-038
M39016/41-039
M39016/41-040
M39016/41-060
1 unit terminal strength and
solderability
1/ For retention of qualification or extension of qualification to lower failure rate levels,
all life test data accumulated on MIL-PRF-39016/42 and MIL-PRF-39016/43 may
be used in addition to MIL-PRF-39016/41 data. Prior to performance of retention of
qualification testing, the relay manufacturer shall preselect the sampling plan.
2/ The number of units required for qualification testing shall be increased as
required in Q5, MIL-PRF-39016, if the relay manufacturer elects to test the number
of units permitting one or more failures. Prior to performance of qualification
inspection testing, the relay manufacturer shall preselect the sampling plan.
Qualification inspection (reduced testing) (sample size - 2 units each coil voltage and 1 unsealed unit): See
table III.
If the relays produced for MIL-PRF-39016/41 are similar in construction and design except for the suppressor
and steering diodes to the relays produced for MIL-PRF-39016/42 and MIL-PRF-39016/43, then reduced
testing for qualification of MIL-PRF-39016/41 relays may be performed concurrent with or subsequent to
successful qualification of MIL-PRF-39016/42 and MIL-PRF-39016/43.
TABLE III. Qualification inspection (reduced testing).
Examination or test
2 units each coil voltage - Q1 qualification
inspection table
1 unsealed sample unit for internal examination.
7