MIL-PRF-39016/28F
TABLE I. Dash numbers and characteristics. 1/ 2/
Over
temp-
At 25°C
Dash numbers 3/
Coil voltage
erature
V dc 6/
range
Coil circuit current
Speci-
Coil
Specified
6/ 7/ 8/
Lead
resist-
Lead Spreader
pickup
fied
Lead
(mA)
length
length
ance
length mounting
(latch/
pickup
1.500
.187
ohms
.500
reset)
(latch/
pads
±.010
min
(fig. 2)
reset)
min
7/
value
Rated
Max
Min
Max
(voltage)
5/
value
4/
(ref. only)
(V dc)
(voltage)
(V dc)
013
019
025
031
5.0
6.0
48
104.2
75.8
3.5
4.5
014
020
026
032
6.0
8.0
97
63.0
46.9
4.1
5.5
015
021
027
033
9.0
12
280
33.7
26.0
6.3
7.8
016
022
028
034
12
16
500
25.5
20.0
8.0
10
017
023
029
035
18
24
1,130
17.2
13.7
11.6
14.5
018
024
030
036
26.5
32
2,000
14.4
11.6
15.4
19
1/ Each relay possesses high level and low level capabilities. However, relays previously tested or used above 10
mA resistive at 6 V dc maximum or peak ac open circuits not recommended for subsequent use in low level
applications.
2/ WARNING: When latching relays are installed in equipment, the latch and reset coils should not be pulsed
simultaneously. Coils should not be pulsed with less then the nominal coil voltage and the pulse width should
be a minimum of three times the specified operate time of the relay. If these conditions are not followed, it is
possible for the relay to be in the magnetically neutral position.
3/ The suffix letter L, M, P, or R to designate the applicable failure rate level shall be added to the applicable listed
dash number. Failure rate level (percent per 10,000 cycles): L, 3.0; M, 1.0; P, 0.1; R, 0.01. Example, 013L - -
- - - -036R.
4/ 1.500 leads are inactive for new design.
5/ Relays supplied with spreader mounting pads (-031 through -036) shall have the spreader mounting pad rigidly
attached.
6/ CAUTION: The use of any coil voltage less than the rated coil voltage will compromise the operation of the
relay.
7/ Coil resistance not directly measurable at relay terminals. When rated voltage is applied to the coil terminals,
the coil current must be within the limits shown. Measure at 25°C at nominal voltage for 5 seconds maximum.
8/ Delete "Coil resistance" and substitute "Coil current" test in all inspection tables of MIL-PRF-39016.
6