MIL-PRF-39016/12G
9. All leads shall be electrically insulated from the case, except for lead terminal -X2Y2, circuit diagram I, which is
grounded to the case.
10. Circuit diagram shown on part is the terminal view.
11. Terminal numbers show above for reference only. Numbers do not appear on relay.
FIGURE 3. Dimensions and configuration relay with spreader mounting pad attached.
REQUIREMENTS:
CONTACT DATA:
Load ratings:
High level (relay case grounded):
Resistive:
1.0 ampere at 28 V dc.
250 milliamperes at 115 V ac 60 and 400 Hz case not grounded.
100 milliamperes at 115 V ac 60 and 400 Hz case grounded.
Inductive load: 0.2 ampere at 28 V dc with 0.32 henry inductance.
Lamp: 0.10 ampere at 28 V dc.
Low level: 10 to 50 µA at 10 to 50 mV dc or peak ac.
Intermediate current: Applicable.
Contact resistance or voltage drop:
Initial: 0.125 ohm maximum (0.150 ohm maximum with spreader mounting pad attached).
High level:
During life: Not more than 5 percent of open circuit voltage.
After life: 0.225 ohm maximum (0.250 ohm maximum with spreader mounting pad attached).
Low level:
During life: 33 ohms maximum.
After life: 0.175 ohm maximum (0.200 ohm maximum with spreader mounting pad attached).
Intermediate current:
During: 1 ohm maximum.
After: 0.225 ohm maximum (0.250 ohm maximum with spreader mounting pad attached).
Contact bounce: 2.0 milliseconds maximum (applicable to failure rate level "L").