MIL-PRF-28750/10C
REQUIREMENTS:
SCREENING: Mechanical shock or constant acceleration shall be in accordance with MIL-PRF-28750,
except the constant acceleration shall be performed at 100 g's.
MECHANICAL REQUIREMENTS:
Weight: 6 ounces maximum.
Seal: (Solder or weld) MIL-STD-202, method 112, test condition A, except temperature +125°C
+0°C, -5°C.
Dimensions and configuration: See figure 1.
Terminals:
Terminal strength: 5 pounds pull.
Terminal solderability: Applicable.
Terminal finish: Corrosion resistant material. Corrosion resistant material such as gold plating are
considered acceptable.
INPUT REQUIREMENTS:
Input voltage range: 4.0 V dc to 32.0 V dc.
Assured turn-on voltage: ≤ 4.0 V dc.
Assured turn-off voltage: ≥ 1.0 V dc.
Input current: 16 mA maximum at 32 V dc.
1
Turn-on time:
maximum.
2 (line frequency)
1
Turn-off time:
maximum.
(line frequency)
Bias current: Not applicable.
OUTPUT REQUIREMENTS:
Output voltage range: 25 V ac to 250 V ac, 45 Hz to 440 Hz.
Rated output current: 25 A, ac maximum (see figure 2 and figure 3).
Rated output voltage: 220 V maximum, 400 Hz.
Output voltage drop: 1.5 V rms maximum.
Output leakage current: 10 mA, ac maximum at 220 V ac, 400 Hz.
Crosstalk: Not applicable.
Transient voltage: MIL-STD-704A, figure 3, curve 1, 180 volts, 5 seconds.
Electric system spike: Not applicable.
Overload: 80 amperes.
DC offset voltage: ±150 mV maximum.