MIL-DTL-26126C
TABLE I. First article inspection.
Relay
Relay Relay
Requirement
Test
Test
Relay
1
2
3
4
paragraph
paragraph
Visual and mechanical
X
X
X
X
3.1, 3.3, 3.4,
4.6.1
examination
3.7, and 3.9
X
X
X
X
3.5.1
4.6.2
X
Dielectric withstanding voltage
X
X
X
3.5.2
4.6.3
X
Calibration
X
3.5.3
4.6.4
X
Endurance
3.5.4
4.6.5
Overload
X
X
3.5.5
4.6.6
High temperature
X
X
3.5.6
4.6.7
Low temperature
X
Vibration:
3.5.7.1
4.6.8.1
X
Endurance
3.5.7.2
4.6.8.2
X
X
Calibration
3.5.8
4.6.9
X
Low temperature altitude
X
3.5.9
4.6.10
X
Acceleration
X
3.5.10
4.6.11
X
Shock (specified pulse)
3.5.11
4.6.12
Fungus resistance 1/
X
3.5.12
4.6.13
Stray magnetic fields
X
3.5.13
4.6.14
Humidity
X
3.5.14
4.6.15
Salt spray
X
3.5.15
4.6.16
Thermal shock
X
X
X
X
3.5.16
4.6.17
Seal
X
X
X
3.5.17
4.6.18
Resistance to solvents
1/ Type I relays only.
TABLE II. Group A inspection.
Examination or test
Requirement
Method
paragraph
paragraph
Visual and mechanical examination
3.1, 3.3, 3.4,
4.6.1
(external) 1/
3.7, and 3.9
Dielectric withstanding voltage
3.5.1
4.6.2
Calibration
3.5.2
4.6.3
Seal
3.5.16
4.6.17
1/ Physical dimensions shall be measured on 5 percent of the sample
units only.
4.5 Test conditions.
4.5.1 Cable size. Cable used in any of the specified tests shall be of the sizes specified in
MIL-W-5088 as determined by the rated load of the relay.
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business