MIL-DTL-12109/21B
a. The stroke test shall be performed during functional (operating) test.
b. Weight shall be confirmed by any approved method.
c. Testing for dielectric withstanding voltage shall as follows:
Test voltage of 1000 volts root mean square at 60 Hertz (Hz) in frequency and shall approximate,
as closely as possible, a true sine wave in form. The voltage shall be applied between coil
terminal and ground metal parts for at least 60 seconds. Test voltage shall be raised from zero to
60 Hz in frequency at a rate of approximately 500 volts per second.
NOTES:
PART OR IDENTIFYING NUMBERS (PIN):
M12109/21-1 (Former part number 7791685 with weapon designation M60C)
M12109/21-2 (Former part number 75F20924 with weapon designation M60E2)
CHANGES FROM PREVIOUS ISSUE: The margins of this specification sheet are marked
with vertical lines to indicate where changes from the previous issue were made. This was done
as a convenience only and the Government assumes no liability whatsoever for any inaccuracies
in these notations. Bidders and contractors are cautioned to evaluate the requirements of this
document based on the entire content irrespective of the marginal notations and relationship to
the last previous issue.