AN3335
REVISION 5
Overload current: Not applicable.
Rupture current: Not applicable.
Coil data:
Nominal operating voltage:
Coil: 28 volts DC.
Contacts: 400Hz, 115/200 Volts AC or 28 Volts DC.
Maximum continuous coil voltage: 29 volts.
Pickup voltage: 18 volts.
Hold voltage: 7 volts
Dropout voltage: 1.5 volts.
Rated duty: Continuous.
Coil current: 0.25 amperes, maximum at 29 volts DC.
Physical data:
Weight: 0.5 pounds, maximum.
Qualification by similarity: See MIL-PRF-6106.
Retention of qualification: To retain qualification, the manufacturer shall submit group A acceptance reports
on a yearly basis to the qualifying activity.
Quality conformance inspection: Performance of groups B and C tests are not applicable.
Part or Identifying Number (PIN): AN3335-1.
Referenced documents:
MIL-PRF-6106
Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the
extent of the changes.
Custodian:
Preparing activity:
Army - AV
DLA - CC
Air Force - 85
DLA - CC
(Project 5945-2011-020)
Review activity:
Air Force - 99
NOTE: The activities listed above were interested in this document as of the date of this document. Since
organizations and responsibilities can change, you should verify the currency of the information above using the
ASSIST Online database at https://assist.daps.dla.mil/ .