Coil data:
Nominal coil voltage: 28 volts.
Maximum operating voltage: 29 volts.
Pickup voltage: 18 volts.
Dropout voltage: 2 volts, minimum; 7 volts, maximum.
Rated duty: Continuous.
Coil current: 0.25 amperes, maximum.
Physical data:
Weight: 0.5 pounds, maximum.
Qualification by similarity: See MIL-PRF-6106.
Retention of qualification: To retain qualification, the manufacturer shall submit group A acceptance reports
on a yearly basis to the qualifying activity.
Quality conformance inspection: Performance of groups B and C tests are not applicable.
Part or Identifying Number (PIN): AN3320-1.
Custodian:
Preparing activity:
Army - AV
DLA - CC
Air Force - 85
DLA - CC
(Project 5945-2010-026)