MS27751K
Inches |
mm |
Inches |
mm |
.002 |
0.05 |
.375 |
9.52 |
.005 |
0.13 |
.437 |
11.10 |
.010 |
0.25 |
1.91 |
48.5 |
.031 |
0.79 |
2.000 |
50.80 |
.10 |
2.5 |
2.44 |
62.0 |
.138 |
3.51 |
2.45 |
62.2 |
.170 |
4.32 |
2.50 |
63.5 |
.190 |
4.83 |
3.13 |
79.5 |
.203 |
5.16 |
NOTES:
1. Dimensions are in inches.
2. Unless otherwise specified, tolerance is ±0.03 for 2 place decimals and ±0.010 for 3 place decimals.
3. Metric equivalents are given for general information only.
4. Polarity indication applies to dc coils only.
5. In the event of a conflict between the text of this specification sheet and the references cited herein, the text of this specification sheet shall take precedence.
6. DC versions of this relay must not operate or be damaged by reverse polarity. Semiconductors shall not be used for this purpose.
7. Permanent magnet drive consists of a permanent magnet with its flux path switched and combined with the electromagnetic flux.
8. Additional flat washer may be used for terminal seat.
9. Terminal numbers shall not appear on the relay header. There shall be affixed to the relay a legible circuit diagram that identifies each terminal location.
10. Terminal covers and barriers are required on power terminals.
11. No paint on either side of (2) diagonally opposite mounting flanges, the closest flange to the A1 terminal and the opposite flange.
FIGURE 1. Dimensions and configuration - Continued.