MS27749F
Vibration - sinusoidal: G-level 30 g's.
Frequency range 10 - 3,000 Hz. Vibration - random:
Applicable specification: MIL-STD-202, method 214.
Test condition: IG.
Duration: 15 minutes each plane. Acceleration 15 g's.
Physical data:
Dimensions and configurations: See figure 1. Weight: 0.938 pound maximum.
Part or Identifying Number (PIN): MS27749- (dash number from table II). Qualification by similarity: See MIL-PRF-6106.
TABLE I. Rated contact load (amperes per pole) case grounded.
Type of load |
Life operat ing cycles x 103 |
28 V dc |
115 V ac, phase |
115/200 V ac, 3 phase 1/ |
See appro priate notes |
|||||||||
Main |
Aux |
Main |
Aux |
Main |
Aux |
|||||||||
NO |
NC |
NO |
NC |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
400 Hz |
60 Hz |
||||
Resistive 2/ |
50 |
25 |
25 |
25 |
25 |
|||||||||
Inductive |
10 |
12 |
12 |
|||||||||||
Inductive |
20 |
15 |
15 |
|||||||||||
Motor |
50 |
10 |
10 |
10 |
10 |
|||||||||
Lamp |
50 |
5 |
5 |
5 |
5 |
|||||||||
Transfer load |
--- |
--- |
--- |
3/ |
||||||||||
Mechanical life reduced current |
200 |
6 |
6 |
6 |
6 |
|||||||||
Mixed loads |
Applicable per specification |
1/ Absence of value indicates relay is not rated for 3 phase applications.
2/ For full rated load, temperature, and altitude, use number 12 wire or larger. Relays shall be mounted so that
mounting bracket temperature is limited to +135°C maximum.
3/ Transfer load indicates relay is suitable for transfer between unsynchronized ac power supplies at rating indicated.
4
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business