MS27715C
TABLE II. Rated contact load (amperes per pole) (case grounded).
Type of load |
Life operating cycles 3 x 10 |
28 V dc |
115 V ac, 1 phase |
115/200 V ac 3 phase 1/ Main |
240/416 V ac 3 phase 1/ Main |
See appro- priate notes |
||||||||
Main |
Aux |
Main |
Aux |
|||||||||||
NO |
NC |
NO |
NC |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
|||
Resistive |
50 |
150 |
10 |
10 |
150 |
100 |
10 |
150 |
100 |
|||||
Inductive |
50 |
|||||||||||||
Inductive |
10 |
100 |
10 |
10 |
100 |
10 |
100 |
|||||||
Motor |
50 |
100 |
5 |
5 |
100 |
5 |
100 |
|||||||
Lamp |
3 |
3 |
3 |
|||||||||||
Transfer load |
2/ |
|||||||||||||
Mechanical' life (reduced current |
200 |
25 |
2.5 |
2.5 |
||||||||||
Mixed loads |
50 |
10 |
0.10 |
0.10 |
10 |
0.10 |
10 |
1/ 115/200 V ac, 240/416 V ac for 60 Hz ratings. Absence of value indicates that the relay may not be suitable for 3 phase applications.
2/ Transfer load indicates that the relay is suitable for transfer between unsynchronized ac power supplies at the rating indicated.