MS27714F
REQUIREMENTS:
Dash numbers and general characteristics: See table I.
TABLE I. Dash numbers and general characteristics.
Part or Identifying Number |
Coil type |
Terminal type |
Auxiliary contacts |
Maximum weight (pounds) |
MS27714-1 MS27714-2 |
dc ac |
Lug Lug |
Yes Yes |
2.5 2.5 |
Contact data:
Load ratings: See table II.
Initial contact voltage drop: 0.150 volt maximum. After life: 0.175 volt.
Overload current (NO): 800 amperes. Rupture current (NO): 1,000 amperes.
TABLE II. Rated contact load and cycles (amperes per pole).
Type of load |
Life operating cycles x 103 |
28 V dc |
115 V ac, 1 phase |
1/ 115,200 V ac, 3 |
1/ 240/416 V ac, 3 |
||||||||
Main |
Aux |
Main |
Aux |
Main |
Main |
||||||||
NC |
NC |
NC |
NC |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
||
Resistive |
50 |
75 |
10 |
10 |
75 |
50 |
10 |
10 |
75 |
50 |
|||
Inductive |
50 |
||||||||||||
Inductive |
10 |
75 |
10 |
10 |
75 |
10 |
75 |
||||||
Motor |
50 |
75 |
5 |
5 |
75 |
5 |
75 |
||||||
Lamp |
1 |
1 |
1 |
||||||||||
Transfer load 2/ |
|||||||||||||
Mechanical life, reduced load |
200 |
18.75 |
2.5 |
2.5 |
|||||||||
Mixed loads |
50 |
5 |
0.1 |
0.1 |
5 |
0.1 |
5 |
5 |
1/ 115/200 V ac and 240/416 V ac for 400 Hz ratings: absence of values indicates that the relay may not be suitable for 3 phase applications.
2/ Transfer load indicates that the relay is suitable for transfer between unsynchronized ac power supplies at the rating indicated.
Coil data: See table III. Duty rating: Continuous.
RFI specification: MIL-STD-461 (applicable to coil circuits of ac operated relays).
3