MS27706J
REQUIREMENTS:
Dimensions and configuration: See figure 1.
Dash numbers and general characteristics: See table I. Contact data:
Load ratings: See table II.
Maximum contact drop, initial: 0.150 V. After life test: 0.175 V.
Overload current: 80 amperes dc; 120 amperes ac. Rupture current: 100 amperes dc; 150 amperes ac.
Coil data: See table III.
Duty rating: Continuous. Electrical data:
Minimum insulation resistance: Initial: 100 megohms.
After life or environmental test: 50 megohms.
Dielectric strength:
Sea level, 2-5 seconds: |
||
Initial |
After life tests |
|
Coil to case Aux contacts All other points |
1,250 V rms N/A 1,500 V rms |
1,050 V rms N/A 1,125 V rms |
Altitude, 1 minute (80,000 feet):
80,000 ft Coil to case 500 V rms Aux contacts N/A
All other points 500 V rms
Environmental characteristics: Temperature range: -70°C to +125°C. Maximum altitude rating: 80,000 feet. Shock g-level: 25 g's.
Duration: 11 ms.