MS27245R
CONFORMANCE INSPECTION:
Performance of groups B and C tests are not applicable.
Group A acceptance reports shall be submitted to the qualifying activity on a yearly basis in order to retain qualification for this military specification sheet.
Qualification by similarity: See MIL-PRF-6106.
TABLE I. Dash numbers and characteristics.
PIN number MS27245- |
Type |
Coil |
Terminal type |
Mounting socket |
Auxiliary contacts |
Max weight in pounds |
1 |
I |
dc |
Plug-in |
Flange |
N/A |
0.08 |
2 |
I |
dc |
Plug-in |
Stud |
N/A |
0.23 |
1/ 3 |
I |
dc |
Plug-in |
Flange |
N/A |
0.08 |
4 |
I |
dc |
Printed wire (PW) |
Stud |
N/A |
0.23 |
5 |
I |
dc |
Solder hook |
Stud |
N/A |
0.23 |
6 |
I |
dc |
Solder hook |
Stud |
N/A |
0.23 |
1/ All tests specified in each subgroup of the Group A inspection table of MIL PRF 6106 are applicable to
3.
TABLE II. Operating characteristics.
PIN MS 27245- |
Coil data |
Time - (milliseconds maximum) |
|||||||||||||||
Coil |
Nominal |
Max |
Max pick-up voltage |
Hold vol- tage 2/ |
Drop out volt- age 2/ |
Oper -ate 3/ |
Rel- ease 4/ |
Contact Bounce |
|||||||||
Volts 1/ |
Freq Hz |
n Res ±10% |
Volts |
Amp |
Nor- mal 2/ |
High temp test |
Cont cur- rent test |
Main |
Aux |
||||||||
NO |
NC |
NO |
NC |
||||||||||||||
MS27245-1 |
X1,X2 |
28 |
dc |
300 |
29 |
.12 |
18 |
18 |
19.8 |
7.0 |
1.0 |
10 |
10 |
2 |
5 |
--- |
--- |
MS27245-2 |
X1,X2 |
28 |
dc |
300 |
29 |
.12 |
18 |
18 |
19.8 |
7.0 |
1.0 |
10 |
10 |
2 |
5 |
--- |
--- |
MS27245-3 |
X1,X2 |
28 |
dc |
300 |
29 |
.12 |
18 |
18 |
19.8 |
7.0 |
1.0 |
10 |
10 |
2 |
5 |
--- |
--- |
MS27245-4 |
X1,X2 |
28 |
dc |
300 |
29 |
.12 |
18 |
18 |
19.8 |
7.0 |
1.0 |
10 |
10 |
2 |
5 |
4 |
4 |
MS27245-5 |
X1,X2 |
28 |
dc |
300 |
29 |
.12 |
18 |
18 |
19.8 |
7.0 |
1.0 |
10 |
10 |
2 |
5 |
--- |
--- |
MS27245-6 |
X1,X2 |
28 |
dc |
300 |
29 |
.12 |
18 |
18 |
19.8 |
7.0 |
1.0 |
10 |
10 |
2 |
5 |
--- |
--- |
1/ Caution: Use of any coil voltage less than nominal coil voltage will compromise the operation of the relay.
2/ Over the temperature range.
3/ With rated coil voltage.
4/ From rated coil voltage.
5
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business