MS25272K
TABLE II. Operating characteristics.
ease
1/ CAUTION: Use of any coil voltage less than rated coil voltage will compromise the operation of the relay.
2/ Over the temperature range.
3/ With nominal coil voltage.
4/ From nominal coil voltage.
5/ MS25272-A1 may be used on 60 Hz if maximum ambient temperature is +85°C (maximum coil current shall be
0.0777 ampere).
TABLE III. Rated contact load (amperes per pole) (case grounded).
Type of load |
Life operat ing cycles x 103 |
28 V dc |
115 V ac, 1 phase |
115/200 V ac, 3 phase 1/ |
See appro priate notes |
|||||||||
Main |
Aux |
Main |
Aux |
Main |
Aux |
|||||||||
NO |
NC |
NO |
NC |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
|||
Resistive |
100 |
10 |
10 |
10 |
6 |
10 |
6 |
|||||||
Inductive |
100 |
|||||||||||||
Inductive |
20 |
6 |
6 |
6 |
4 |
6 |
4 |
|||||||
Motor |
100 |
4 |
4 |
4 |
3 |
4 |
3 |
|||||||
Lamp |
100 |
2 |
2 |
2 |
1.5 |
2 |
1.5 |
|||||||
Transfer load |
2/ |
|||||||||||||
Mechanical life reduced current |
400 |
2.5 |
2.5 |
2.5 |
2 |
2.5 |
2 |
|||||||
Mixed loads |
Applicable per specification |
1/ Absence of value indicates relay is not rated for 3-phase applications.
2/ Transfer load indicates relay is suitable for transfer between unsynchronized ac power supplies at rating indicated.
Environmental characteristics.
Temperature range -70°C to +125°C Max altitude rating 80,000 ft
Shock G-level 50 g's
Duration 11 ms
Max duration contact opening 10 µs
Vibration - sinusoidal
G-level 10 g's
Frequency range 5 - 1,500 Hz
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business